Pressure Sensors...
...Low-Level (mV Output), High-Level (Volt Output), High-Level (Ratiometric),
Transmitters (4-20mA Output)

Pressure sensors or pressure transducers are used to measure the pressure in a wide variety of systems. Normally a maximum pressure range of 1.5 times the maximum pressure in your system must be selected due to the pressure spikes or continuous pulsations appearance in most hydraulic or process control systems. These short duration spikes can be five to ten times or more the maximum pressure, thus destroying the pressure transducers where a pressure gauge may have lasted for years withought trouble. You must always keep in mind that specyfying a higher range is not always a solution because you will sacrifice resolution. Using a snubber to clip the spikes is also a tradeoff due to the fact that it slows the response time of the transducer. We have indexed the pressure tranducers according to their Output Level and Type (Voltage - Amperage).

Low-Level [Table #1]
Low-level pressure sensors-transducers have an output range of 20 to 100 mV. They are used in applications such as: Medical Equipment, Filter Monitoring, HVAC Equipment, Barometric Pressure, Pneumatic Equipment, Gas Flow Monitoring, Clean Rooms and Leak Detection
X=YES XCX... XUX... TO5... CPX... CPC...
Model DNCDNDNP DN D G GGCGH
Range 4 Inches W.C./ 0.3-240PSI (10mb-16b) 4 Inches W.C./ 0.3-150PSI (10mb-10b)
Compensated xxx -- - -xx
Pressure Type
gage/diff./abs.
g/d/ag/d/ag/d/a g/d/ag/d/a g/d/a g/ag/ag/a
Accuracy (+/-) 1,0%0,5%0,25% -- - -1,0%0,5%
Temperature Range (in Celcium degrees)
Compensation 0 to 70 ( 10mb 0 to 50 ), Operation -40 to 85, Storage -40 to 125
Max. Pressure
Proof pressure min. 3x rated range ( 2x for greater than 100PSI )
Burst pressure min. 5x rated range ( 3x for greater than 100PSI )
Excitation Voltage
Compensated Sensors 3 - 30 V Uncompensated Sensors 3 - 10 V
Output Voltage 20 - 100 mV ( @ Full Scale and V-exitattion = 12 V )

Low-Level [Table #2]
Low-level pressure sensors-transducers have an output range of 20 to 100 mV. They are used in applications such as: Medical Equipment, Filter Monitoring, HVAC Equipment, Barometric Pressure, Pneumatic Equipment, Gas Flow Monitoring, Clean Rooms and Leak Detection
X=YES XPX XPC...FS* XPX XPC XPX XPC...DF XPX XPC
Model GFSG*CG*H GTGTCGTH DFSSCSH DTDTCDTH
Range 4 Inches W.C./ 0.3-150PSI (10mb-10b)
Compensated -xx -xx -xx -xx
Pressure Type
gage/diff./abs.
g/ag/ag/a g/ag/ag/a g/dg/dg/d g/dg/dg/d
Accuracy (+/-) -1,0%0,5% -1,0%0,5% -1,0%0,5% -1,0%0,5%
Temperature Range (in Celcium degrees)
Compensation 0 to 70 ( 10mb 0 to 50 ), Operation -40 to 85, Storage -40 to 125
Max. Pressure
Proof pressure min. 3x rated range ( 2x for greater than 100PSI )
Burst pressure min. 5x rated range ( 3x for greater than 100PSI )
Excitation Voltage
Compensated Sensors 3 - 30 V Uncompensated Sensors 3 - 10 V
Output Voltage 20 - 100 mV ( @ Full Scale and V-exitattion = 12 V )

High-Level
High-Level pressure sensors-transducers have an output range of 1 to 6 Vdc. They are used in applications such as: Air Conditioning and Refrigeration, Air and Gas Compressors, Dymometers and Engine Test Stands, Engine Controls and Monitors, Enviromental Control Systems, Hydraulic and Pneumatic Controls, Process Control Equipment, Robotics, Transmissions and Water Management.
Model EA and EAF features:
Low Cost / Amplified Output, Valox Case,
1% Accuracy, 0 - 6 to 0 - 5000 PSIG, 1 - 6 Vdc output, Compatible with microprocessors.
Range PSI G: 0-6 15 25 0-50 100 200 300 0-500 1000 2000 5000
Proof Pressure 2 x rated range 2 x rated range 1.5 x rated range
Burst Pressure 20 x rated range 10 x rated range 5 x rated range
Material in Contact.: Brazed assembly of 300 series stainless steel
Shock.: 50 g's peak ( 5 milliseconds )
Vibration.: Meets MIL - STD 810C, Figure 514-5, Curve AK, Time Schedule II
Weight.: Less than 85 gr ( 3 oz ) with connector
Full Scale Output.:EA : 5 +/- 0.1 Vdc @ 25'C, EAF : 5 +/- 0.1 kHz @ 25'C,
Zero Output.: EA : 1.0 +/- 0.15 Vdc @ 25'C, EAF : 1.0 +/- 0.15 kHz @ 25'C,
Exitation.: EA : 8 to 24 Vdc @ 15 mA niminal, EAF : 10 to 20 Vdc @ 20 mA niminal
Output Current.: Source : 10 mA, Sink : 5 mA ( 8 mA EAF )
Output Voltage.: EAF Only : 18 Vdc
Enable.: Voltage ( inhibit, EAF only ) : 8 Vdc max., Current ( Source, EAF Only ) : 9 mA max.
Insulation Resistance.: 1000 M @ 50 Vd
Electrical Connection.: Automotive type, Valox housing with crimp pins ( supplied )
Accuracy.: +/- 1 F.S.O. including effects of Non-Linearity, Hysteresis and Non-Repeatability
Operating Temperature Range.: EA : - 55' to 100'C ( -67' to 212'F ) EAF : - 40' to 85'C ( -40' to 185'F )
Compensated Temperature Range.: - 1' to 85'C ( 30' to 185'F )
Thermal Effect on Zero.: Less than +/- 1 % F.S.O. - any 55'C change within the compensated range
Thermal Effect on Full Scale Output.: Less than +/- 1 % within the compensated range

High-Level Ratiometric
High-Level Ratiometric pressure sensors - transducers have a signal output range of 0.25 to 4.25 V. They are used in applications such as : Medical Equipment, Filter Monitoring, Instrumentation, Gas Flow, Clean Rooms and Leak Detection.
X=YES XCA4... XCA5... NT142-144...
Model GNDNAN GNDNAN RDA
Range 4 Inches W.C./ 0.3-150PSI (10mb-10b) 4 Inches W.C./ 0.3-240PSI (10mb-16b)
Compensated xxx xxx xxx
Pressure Type
gage/diff./abs.
gda gda gda
Accuracy (+/-) 0,5%0,5%0,5% 0,5%0,5%0,5% (0,25%)
0,5%
(0,25%)
0,5%
(0,25%)
0,5%
Excitation Voltage 3 - 16 Vdc 8 - 30 Vdc
Output Signal 0.24 - 4.25 V 1 - 6 V 1 - 6 V
Ratiometric
(Exitation)
x
(5 V)
x
(5 V)
x
(5 V)
x
(8 V)
x
(8 V)
x
(8 V)
---
Internal
Reference
--- --- xxx
Temperature Range (in Celcium degrees)
Compensation 0 to 70 ( 10mb 0 to 50 ), Operation -40 to 85, Storage -40 to 125
Max. Pressure
Proof pressure min. 3x rated range ( 2x for greater than 100PSI )
Burst pressure min. 5x rated range ( 3x for greater than 100PSI )

Transmitters 4-20mA Output
Pressure Transmitters are sensors with precise signal conditioning electronic circuitry. Available on a PC-board package for 2-wire current loop systems withought seperate voltage supply for the sensor board, and in a Non-corrosive Metalhousing (Siloumin), designed for use in hursh enviromental conditions like : Splashing Seawater, Industrial Fabrication, Outdoor Applications etc.
X=YES XC420... NT7000...
Model RDA RA
Range 4 Inches W.C./ 0.3 - 240 PSI ( 10mb-16b )
Compensated xxx xx
Pressure Type
gage/diff./abs.
gda ga
Accuracy (+/-) (0,25%)
0,5%
(0,25%)
0,5%
(0,25%)
0,5%
0,5%0,5%
Excitation Voltage 6.5 - 30 Vdc 9 - 30 Vdc
Output Signal 4 - 20 mA (0) 4 - 20 mA
0 - 10 V
Temperature Range (in Celcium degrees)
Compensation 0 to 70 ( 10mb 0 to 50 ), Operation -40 to 85, Storage -40 to 125
Max. Pressure
Proof pressure min. 3x rated range ( 2x for greater than 100PSI )
Burst pressure min. 5x rated range ( 3x for greater than 100PSI )

Load sensors... U N D E R - C O N S T R U C T I O N
Load Cells ....................................................................................................................................................................